Table of Contents Table of Contents
Previous Page  386-Methanol Operations / 748 Next Page
Information
Show Menu
Previous Page 386-Methanol Operations / 748 Next Page
Page Background

Met

h

anol

Op

erations

BOS-PRD-07.900609

Fire Safety precautions:

x

Smoking

shall

be prohibited everywhere during the operation even inside (in case ventilation and

accommodation A/C would fail, pressuring of accommodation would no longer be assumed and

methanol gas may enter)

x

Electrical equipment

shall

be explosive proof;

x

Alcohol Resistant - Aqueous Film Forming Foam of the alcohol-resistant type (AR-AFFF) with 6%

foam proportioning (with water) equipment is advised for use on methanol fires;

x

Dry Chemical extinguishers

shall

be accessible for small fires. An adequate supply of hand held and

wheeled types

shall

be available;

x

Hydrants

shall

be strategically placed with adequate hoses – Foam guns are placed and orientated

as per classification society approval to cover the dangerous area

x

Small spills

shall

be remediated with sand, earth or other non-combustible absorbent materials, and

the area then flushed with water. Larger spills

shall

be diluted with water.

4

.1.

4 E

n

v

iron

m

ental

p

rote

c

tion

Methanol biodegrades easily in water. Methanol in high concentration in fresh water or salt water can have

short term harmful effects on aquatic life within the immediate spill area.

SMPEP/SOPEP equipment

shall

be ready for use on deck. Scuppers

shall

be closed and plugged to prevent

any methanol spillage to the sea.

4

.

2

Met

h

anol trans

f

er

4

.

2

.1

J

o

b p

re

p

aration

The methanol transfer

shall

be prepared according to company’s standards, using G-JSA 15 (S-JSA if

developed by the vessel), Check-list and holding a tool box meeting as mentioned on section 9.

All electric power equipments in direct vicinity of the Methanol transfer station and pipings,

shall

be of an

explosion proof type (including lighting and portative UHF).

Battery replacement

shall

be done in a safe area, inside accommodation.

Suitable PPE

shall

be worn. Respiratory masks, face shield, chemical suits, certified methanol resistant

chemical proof boots and gloves, hard hat.

The Nitrogen

shall

be available on sufficient volume to provide a continuous loading /offloading of the whole

quantity of methanol. Nitrogen is either produced on board by the nitrogen generator, supplied by the FPSO

(receiver) or chemical tanker (supplier), or available in a tank loaded on main deck.

A SCBA shall be placed at the most strategic place in order to cope with emergency recovery of personnel

inside the nitrogen room. Ventilation

shall

be on in the nitrogen plant room during the methanol operation.

The SCBA

shall

be worn during transfer phases when entering the nitrogen plant room, as nitrogen exposure

may occur, unless the ventilation is kept on. An O2 detector is checking atmosphere in this room during

operations.

A stretcher and resuscitation kit

should

be placed close enough to the nitrogen plant room.

Methanol transfer pumps emergency stops shall be tested.

The list and trim of the vessel

should

be considered. A good setting allows a better flow of methanol when

offloading and will keep the pump running longer with less methanol left over in the tanks at the end.

Version 04. Original date: 22/06/2012. Version date: 31/12/2014. Valid version only on QMS site. Uncontrolled document when printed.

Procedure prepared by: BOS Head of Operations. Approved by: BOS Head of Operations. Validated by: BOS Quality Representative.

7 / 15

386