DP Op
erations
P
rocedure
BOS-PRD-0701.900606
4.
3 DP Sy
ste
m
certi
f
ication and veri
f
ication
4.
3
.1
DP
F
MEA
x
DP FMEA (Failure Modes and Effects Analysis)
proving trials are reviewed at the delivery date of the
vessel. This latter
shall
be done after :
1 Modifications on DP system or set up new Position Reference System for example;
2 Upgrades, DP class 1 to DP class 2 for example;
3 Charterer request;
4 After 5 years.
x
This DP trial is compulsory for vessel DP class 2 or 3 and may be requested by charterer for DP
OSV Capability 1.
x
DP FMEA is performed by a Third party.
x
Last FMEA report
shall
be archived in appropriate binder as per
BOS SMS vessel filing system
and
is a part of DP vessel familiarization.
x
FMEA proving trial(s) are described in
IMCA guidelines M 166 “Guidance on Failure Modes & Effects
Analyses (FMEAs).
4.
3
.
2 A
nnual
DP
trials
x
This DP test is performed on a yearly basis after the FMEA date of anniversary +/- 3 months for all
DP class vessels.
x
A Third party may be contracted to do annual DP trials for BOS vessels. A Company’s
M
aster
,
C
hie
f
E
ngineer
or a
DP
e
xp
ert
, external of the vessel, may perform annual DP trials, using DP annual test
report as per
IMCA Guidelines M 190 “Guidance for Developing and Conducting Annual DP Trials
Programmes for DP Vessels”
.
x
Last Annual DP trials report
shall
be printed and archived in binder 113C, as per BOS SMS Vessel
Filing System.
x
Annual DP trial informations are described in
IMCA guidelines M 190 “Guidance for Developing and
Conducting Annual DP Trials Programmes for DP Vessels”
.
4.
3
.
3 DP C
a
p
a
b
ilit
y p
lots
x
Vessel’s Master
shall
ensure that DP Capability plots are available on board.
x
Capability plots
shall
be printed and archived in appropriate binder as per BOS SMS Vessel Filing
System.
Version 03. Original date: 13/02/2014. Version date: 31/12/2014. Valid version only on QMS site. Uncontrolled document when printed.
Procedure prepared by: BOS Project Coordinator. Approved by: BOS Senior of Operations Director. Validated by: BOS Quality Representative.
7 / 11
375




