Table of Contents Table of Contents
Previous Page   461/ Dynamic Positioning Operations / 992 Next Page
Information
Show Menu
Previous Page 461/ Dynamic Positioning Operations / 992 Next Page
Page Background

Dy

na

m

ic

P

ositionin

g

O

p

erations

BOS-

P

RD-2

6

.900

6

0

6

4

.

5

.

3 A

nn

u

al

DP

trials

T

h

i

s

D

P

test

i

s

performed on

a

year

l

y bas

i

s

after

the

F

MEA date of

ann

i

versary

+

/

-

3 months

for

a

ll D

P

c

l

ass

vesse

l

s

.

A

T

h

i

rd party may be

contracted

to do annua

l D

P

tr

i

a

l

s

for

BOS

vesse

l

s

.

A Company

’

s

Master

,

C

hie

f

E

n

g

ineer

or

a

DP

e

xp

ert

,

e

x

terna

l

of

the

vesse

l,

may perform

annua

l D

P

tr

i

a

l

s

,

us

i

ng

D

P annua

l

test

report

as

per

“

I

MCA

G

u

i

de

li

nes M

1

90

“

G

u

i

dance

for

D

eve

l

op

i

ng

and Conduct

i

ng Annua

l D

P

T

r

i

a

l

s Programmes

for

D

P

V

esse

l

s

”

un

l

ess

c

li

ent

re

q

uest

a

th

i

rd

party attendance

.

L

ast Annua

l D

P

tr

i

a

l

s

report

shall

be

pr

i

nted

and arch

i

ved

i

n b

i

nder 113C

,

as

per

SMS Vessel Filing System

.

Annua

l D

P

tr

i

a

l i

nformat

i

on are descr

i

bed

i

n

I

MCA

gu

i

de

li

nes M

1

90

“

G

u

i

dance

for

D

eve

l

op

i

ng

and

Conduct

i

ng Annua

l D

P

T

r

i

a

l

s Programmes

for

D

P

V

esse

l

s

”.

4

.

5

.

4 C

riticalit

y A

nal

y

ses an

d

p

lanne

d

m

aintenance

R

eference

to

the

I

M

O

“

IS

M Code

”

sect

i

on

1

0.

3 prov

i

s

i

ons

to

D

P

systems

.

B

y do

i

ng

so

,

the

D

P

system

must

be

i

dent

i

f

i

ed

as

safety

cr

i

t

i

ca

l

system

(

systems where

a

sudden operat

i

ona

l

fa

il

ure

may

resu

l

t

i

n

hazardous

s

i

tuat

i

ons

)

and

p

l

anned

i

nspect

i

ons

,

test

i

ng

and

ma

i

ntenance

procedures

must be

i

ncorporated

i

n

the

BO

U

RBON S

h

i

p Management

O

rgan

i

zat

i

on

’

s

S

M

S.

T

he

BB

S

Mana

g

in

g

D

irector

shall

ensure

that

for

the

D

P

system

(

f

i

gure

3

)

regu

l

ar

i

nspect

i

on

,

per

i

od

i

c

test

i

ng

and

p

l

anned ma

i

ntenance

procedures

are

i

nc

l

uded

i

n

the

PM

S

to

ensure

the

D

P

system

i

s

k

ept

and

ma

i

nta

i

ned

i

n a

fu

ll

y operat

i

ona

l

cond

i

t

i

on

. T

he effect

i

veness

of

the

procedures

shall

be

guaranteed

through:

I

dent

i

f

i

cat

i

on of

D

P

system

,

subsystems

or

components

based on

the approved

pre

li

m

i

nary

D

P

F

MEA

.

B

y

e

x

tend

i

ng

th

i

s

D

P

F

MEA

by

us

i

ng

a

subsystem

or

components

-

based

CA

, i

n

order

to

spec

i

fy

D

P

ma

i

ntenance

re

l

ated

act

i

v

i

t

i

es

and

D

P

spares

.

T

he

BB

S

Mana

g

in

g D

irector

shall

ensure

that

the

spec

i

f

i

ed

i

nspect

i

ons

,

test

i

ng

,

ma

i

ntenance

act

i

v

i

t

i

es

and

spare

components

are

entered

i

n

the

PM

S

and

are

h

i

gh

li

ghted

as

be

i

ng

assoc

i

ated

to

a

safety

cr

i

t

i

ca

l

system:

D

P

system

shall

be

l

abe

l

ed

“cr

i

t

i

ca

l” i

n PM

S

software

.

D

P

support

systems

and

D

P

support

components

shall

be

l

abe

l

ed

“cr

i

t

i

ca

l” i

n

PM

S

software

, i

f

those

have

not been

assessed

separate

l

y

.

Ma

i

ntenance

act

i

v

i

t

i

es

i

nvo

l

v

i

ng

the

D

P

system

shall

be

l

abe

l

ed

as

“cr

i

t

i

ca

l” i

n

the PM

S

software

.

W

hen

deve

l

op

i

ng

the

procedures

i

n

the

PM

S,

the

BB

S

Mana

g

in

g

D

irector

shall

ta

k

e

i

nto

account

that

the

secondary

purpose

of

perform

i

ng

per

i

od

i

c ma

i

ntenance

and

test

i

ng

i

s

one

of

crew

tra

i

n

i

ng

and assessment

.

Technical

Sup

erinten

d

ent

shall

ensure

that

records

from

the

spec

i

f

i

ed

D

P

system

re

l

ated

i

nspect

i

ons

,

test

i

ng

,

ma

i

ntenance

act

i

v

i

t

i

es

done

, i

nc

l

ud

i

ng

records

on

the use

of

D

P

system

spare

components

are made

i

n

the PM

S

and

that

these

records

are ava

il

ab

l

e dur

i

ng

D

P

ver

i

f

i

cat

i

on

surveys

.

R

eferr

i

ng

to

the

i

nformat

i

on

conta

i

ned

i

n

the

D

P

F

MEA

sect

i

on

of

these

Dynamic Positioning Guidelines

,

upon

rece

i

pt

of

a

M

O

C

anne

x

ed

w

i

th

an

Equipment Change Report

(

not

i

f

i

cat

i

on

)

by

a

Technical

Sup

erinten

d

ent

,

the

BB

S

Mana

g

in

g

D

irector

shall

ensure

that

where

a

l

terat

i

ons

and

add

i

t

i

ons

to

the

D

P

system

are done

,

the CA

and

the PM

S

are

updated

.

As

such:

T

he

pre

li

m

i

nary CA

shall

i

n

i

t

i

a

ll

y

be

vesse

l

ser

i

es

’

gener

i

c

(i

n

th

i

s

case

,

the

report

shall

state

the

names

of

the

vesse

l

s

of

the

ser

i

es

)

and become

vesse

l-

spec

i

f

i

c

dur

i

ng

the

li

fespan

of

the

D

P

S

ystem

.

T

he ma

i

ntenance

spec

i

f

i

ed

i

n

the PM

S

shall

be

vesse

l-

spec

i

f

i

c

.

V

ers

i

on

SF (BOS-

P

RD-0

7

0

1

.000

6

-

ver

.

C

R).O

r

i

g

i

na

l D

ate:

31/1

2

/

20

15

.

V

ers

i

on

D

ate:

N

/A

.

V

a

li

d

vers

i

on

on

l

y

on

QM

S

s

i

te

.

Uncontro

ll

ed

document

when

pr

i

nted

.

Page

15 of

44

Procedure prepared by:

BOS

H

ead

of

O

perat

i

ons

.

Approved

by:

BOS

H

ead

of

O

perat

i

ons

.

V

a

li

dated by:

BOS

Qua

li

ty

R

epresentat

i

ve

.

461